Quality Policy

"Blue Heaven Technologies provides quality education and testing services through adoption of good professional practices and continual process improvement. "

Blue Heaven Technologies provides quality education and testing services through adoption of good professional practices and continual process improvement. 

     – Bobby Singer, President

Confidentiality Statement

In all laboratory operations, Blue Heaven Technologies is committed to safeguarding the confidentiality of our customers, vendors, suppliers, and partners. All information disclosed and indicated as confidential is kept confidential. 

Decision Rule

Regardless of uncertainty, Blue Heaven Technologies will report a statement of compliance based on actual readings of device(s) under test compared to the standard being used. 

Impartiality Statement

In all laboratory operations, Blue Heaven Technologies is committed to independence and impartiality in our dealings with customers, vendors, suppliers, and partners. Blue Heaven Technologies maintains a presence of objectivity, independence, neutrality, and freedom from conflict of interest. 

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed to perform the following types of tests on filters and components with the following operational ranges:

  • Particle Sizes from 7 nanometers up to 200 micrometers
  • Pressure differential readings up to 50” w.g. (12,500 Pa)
  • Air flow rates up to 50,000 ft3/min (85,000 m3/hr.)
  • RH exposure up to 99% non-condensing.
Tests Test Methods
General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size ANSI/ASHRAE 52.2
Air Filter for General Ventilation-Full ISO 16890-1, ISO 16890-2, ISO 16890-3, ISO 16890-4
Air Intake Filter Systems for Rotary Machinery – Static Filter Elements ISO 29461-1
High Resistance Breach Testing BHT WI 5.4-340 (Dry Breach), BHT WI 5.4-341 (Standard Wet Breach), BHT WI 5.4-342 (72 Hour Wet Breach)
Flammability Test AAR RP 559
Baggy Filter Test AAR R807
Filtration Efficiency of Paint Arrestor Systems NESHAP 319
Industrial Intake Filter Testing ISO 5011 section 7.0
Saudi ARAMCO System Testing 32-SAMSS-008 Appendix II
200 Hour Dust Rejection Testing GE Document 221A3087 section 3.2.4.1, GE Document 221A3087 section 4.5
ASHRAE 199 System Testing ANSI/ASHRAE 199
Performance of Room Air Cleaners ANSI/AHAM AC-1
High Efficiency Air Filter Testing EN 1822-1; ISO 29463-3 & -5 [European], ISO 29463-01
Testing ULPA Filters IEST-RP-CC007.3
Flat Sheet Initial Efficiency ANSI/ASHRAE 52.2, ANSI/ASHRAE 52.2 Appendix J; ISO 16890-2, ISO 16890-4
1822 Flat Sheet Efficiency EN 1822-1; ISO 29463-3 [European], ISO 29463-01, ISO 29463-3
Flat Sheet Dust Holding [FSD] BHT WI 5.4-310
Mullen Burst Testing ASTM D3786
Frazier Permeability Testing ASTM D737
Resistance Traverse ASHRAE 52.2
Automotive Engine Intake Filter Testing ISO 5011 section 6.4.2
Cabin Air Filter Testing ISO 11155-1
Respirator N95 Efficiency Screening Test – Flat Sheet or Mask NIOSH N95; Modified TEB-APR- STP 0059
Respirator N95 – Full Test for Efficiency NIOSH N95 – TEB-APR-STP – 0059
Respirator N95 – Test for Resistance NIOSH N95 – TEB-APR-STP – 0003 & 0007
FDA Medical Mask Testing Efficiency ASTM F2299
FDA Medical Mask Testing Resistance EN 14683 Annex C
Requirements for Barrier Face Coverings ASTM F3502
Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System ASTM F1977
HEPA Filtration System Performance of Residential and Commercial Vacuum Cleaners ASTM F3150
Electrostatic Air Cleaners - Ozone Chamber Emissions Testing CSA 22.2 187 Clause 7.4
Electrostatic Air Cleaners – Ozone Testing UL 867
Electrostatic and UVC Air Cleaners Duct Mounted Emissions Test CSA 22.2 187 Clause 7.5, 7.6

A2LA Cert. No. 6298.01) 07/30/2025